小蚂蚁 发表于 2021-11-15 13:25:38

Sun SPARC 小机故障硬盘更换方法

单位的SUN小机硬盘前阵子指示灯 告警,检查发现是硬盘故障,设备早已脱保,如今都是自己维护,网上查询了很多资料,可用的信息太少,还是自己动手丰衣足食的好,也给有类似设备故障的同僚一点参考

一、   系统介绍
操作系统:Solaris 10
文件系统:ZFS
存储池:
-3.2# zpool status
pool: rpool
state: ONLINE
scan: resilvered 144G in 2h10m with 0 errors on Mon Dec 11 13:56:43 2017
config:   
    NAME          STATE   READ WRITE CKSUM
    rpool         ONLINE       0   0   0
      mirror-0    ONLINE       0   0   0
      c0t0d0s0ONLINE       0   0   0
      c0t1d0s0ONLINE       0   0   0
二、故障描述
存储池rpool中一个磁盘故障,待更换:
-3.2# zpool status
pool: rpool
state: DEGRADED
status: One or more devices are faulted in response to persistent errors.
    Sufficient replicas exist for the pool to continue functioning in a
    degraded state.
action: Replace the faulted device, or use 'zpool clear' to mark the device   repaired.
scan: resilvered 197G in 2h24m with 0 errors on Fri May 12 19:15:56 2017
config:
   NAME          STATE   READ WRITE CKSUM
    rpool         DEGRADED   0   0   0
      mirror-0    DEGRADED   0   0   0
      c0t0d0s0FAULTED      9   618   0too many errors
      c0t1d0s0ONLINE       0   0   0

errors: No known data errors
三、操作过程
1.确定磁盘
在换盘过程中,如果无法在外观上确定坏盘,可通过以下命令生成一个10G的文件:
-3.2# mkfile 10G file1目前两块磁盘中,一个已经是坏盘,所以当生成1个10G文件时,在两块磁盘外观上,无故障的磁盘灯会闪烁,不闪烁的则是故障盘。
2.确定引导盘
    bash-3.2# prtconf -vp|grep -i bootpath
    bootpath:'/pci@0,600000/pci@0/scsi@1/disk@0,0:a'确定引导盘为disk0,再换盘前需更换为另外一个dis1进行系统引导
重启操作系统到OK界面:
{0} ok boot disk1 (以disk1磁盘进行引导,在用disk1将系统引导起来后再进行故障盘更换工作)3.更换磁盘
-3.2# zpool offline rpool c0t0d0s0
bash-3.2# zpool status
pool: rpool
state: DEGRADED
status: One or more devices has been taken offline by the administrator.
    Sufficient replicas exist for the pool to continue functioning in a
    degraded state.
action: Online the device using 'zpool online' or replace the device with
    'zpool replace'.
scan: scrub repaired 0 in 2h7m with 0 errors on Thu Jan 24 20:31:42 2019
config:
    NAME          STATE   READ WRITE CKSUM
    rpool         DEGRADED   0   0   0
      mirror-0    DEGRADED   0   0   0
      c0t0d0s0OFFLINE      0   0   0
      c0t1d0s0ONLINE       0   0   0

errors: No known data errors

bash-3.2# df -h   
Filesystem    size   usedavail capacityMounted on rpool/ROOT/s10s_u11wos_24a
            274G   109G   145G    43%    /
/devices      0K   0K   0K   0%    /devices
ctfs         0K   0K   0K   0%    /system/contract
proc         0K   0K   0K   0%    /proc
mnttab         0K   0K   0K   0%    /etc/mnttab
swap         92G   448K    92G   1%    /etc/svc/volatile
objfs          0K   0K   0K   0%    /system/object
sharefs      0K   0K   0K   0%    /etc/dfs/sharetab
fd             0K   0K   0K   0%    /dev/fd
swap         92G    64K    92G   1%    /tmp
swap         92G    72K    92G   1%    /var/run
rpool/export   274G    34K   145G   1%    /export
rpool/export/home 274G    13M   145G   1%    /export/home
rpool             274G   106K   145G   1%    /rpool拔出旧磁盘,插入新磁盘
4.建立磁盘分区表
对于系统盘做镜像,需要将两个磁盘的分区表做成一模一样。
-3.2# devfsadm -C
bash-3.2# format
Searching for disks...done

c0t0d0: configured with capacity of 279.38GB

AVAILABLE DISK SELECTIONS:
   0. c0t0d0 <SUN300G cyl 46873 alt 2 hd 20 sec 625>
      /pci@0,600000/pci@0/scsi@1/sd@0,0
   1. c0t1d0 <SUN300G cyl 46873 alt 2 hd 20 sec 625>
      /pci@0,600000/pci@0/scsi@1/sd@1,0
   2. c3t60060E8005638900000063890000000Cd0 <HITACHI-OPEN-V*19   -SUN-6008-4.94TB>
      /scsi_vhci/ssd@g60060e8005638900000063890000000c
   3. c3t60060E80056389000000638900000000d0 <HITACHI-OPEN-V*6    -SUN-6008-1.56TB>
      /scsi_vhci/ssd@g60060e80056389000000638900000000
   4. c3t60060E80056389000000638900000008d0 <HITACHI-OPEN-V*4    -SUN-6008-1.04TB>oracle
      /scsi_vhci/ssd@g60060e80056389000000638900000008
   5. c3t600507640081002FC0000000000000FCd0 <IBM-2145-0000-5.00TB>
      /scsi_vhci/ssd@g600507640081002fc0000000000000fc
Specify disk (enter its number): 0
selecting c0t0d0

Disk not labeled.Label it now? y#新盘需打标签,2T以上容量可以打EFI标签(打标签会删除磁盘数据)

FORMAT MENU:
    disk       - select a disk
    type       - select (define) a disk type
    partition- select (define) a partition table
    current    - describe the current disk
    format   - format and analyze the disk
    repair   - repair a defective sector
    label      - write label to the disk
    analyze    - surface analysis
    defect   - defect list management
    backup   - search for backup labels
    verify   - read and display labels
    save       - save new disk/partition definitions
    inquiry    - show vendor, product and revision
    volname    - set 8-character volume name
    !<cmd>   - execute <cmd>, then return
    quit
format> p
PARTITION MENU:
    0      - change `0' partition
    1      - change `1' partition
    2      - change `2' partition
    3      - change `3' partition
    4      - change `4' partition
    5      - change `5' partition
    6      - change `6' partition
    7      - change `7' partition
    select - select a predefined table
    modify - modify a predefined partition table
    name   - name the current table
    print- display the current table
    label- write partition map and label to the disk
    !<cmd> - execute <cmd>, then return
    quit
partition> p
Current partition table (original):
Total disk cylinders available: 46873 + 2 (reserved cylinders)
Part      Tag    Flag   Cylinders         Size            Blocks
0       root    wm       0 -    20      128.17MB(21/0/0)   262500
1       swap    wu      21 -    41      128.17MB   (21/0/0)262500
2   backup    wu       0 - 46872      279.38GB   (46873/0/0) 585912500
3 unassigned    wm       0                0      (0/0/0)      0
4 unassigned    wm       0                0      (0/0/0)      0
5 unassigned    wm       0                0      (0/0/0)      0
6      usr    wm      42 - 46872      279.13GB   (46831/0/0) 585387500
7 unassigned    wm       0                0      (0/0/0)      0以上是新盘“c0t0d0”的磁盘的分区结构,
查看之前无故障的磁盘“c0t1d0”的分区结构:
      Tag    Flag   Cylinders       Size               Blocks
0       root    wm       0 - 46872    279.38GB (46873/0/0) 585912500
1 unassigned    wu       0                0 (0/0/0)         0
2   backup    wm       0 - 46872      279.38G (46873/0/0)585912500
3 unassigned    wu       0                0       (0/0/0)      0
4 unassigned    wu       0                0         (0/0/0)    0
5 unassigned    wu       0                0         (0/0/0)    0
6 unassigned    wu       0                0         (0/0/0)    0
7 unassigned    wu       0                0         (0/0/0)    0通过对比可看出新磁盘“c0t0d0”与旧磁盘“c0t1d0”的分区结构是不一样的,由于两块磁盘彼此是镜像的结构,所以在进行数据同步前,先将新磁盘“c0t0d0”的分区按照旧磁盘“c0t1d0”进行分区设置,如下图所示,分区表已经拷贝一模一样,注意磁盘末尾是分片“s2”(分片 2,表示带有 VTOC 标签的整个磁盘。)
-3.2# prtvtoc /dev/rdsk/c0t1d0s2|fmthard -s - /dev/rdsk/c0t0d0s2(新盘)
fmthard:New volume table of contents now in place.#将“c0t0d0s2”的分区按照“c0t1d0s2”的分区表进行复制设置
-3.2# format   # c0t0d0s2的分区表如下所示
Part      Tag    Flag   Cylinders      Size                Blocks
0       root    wm       0 - 46872    279.38GB (46873/0/0)585912500
1 unassigned    wu       0             0   (0/0/0)             0
2   backup    wm       0 - 46872   279.38GB(46873/0/0)585912500
3 unassigned    wu       0             0(0/0/0)             0
4 unassigned    wu       0             0(0/0/0)             0
5 unassigned    wu       0             0(0/0/0)             0
6 unassigned    wu       0             0(0/0/0)             0
7 unassigned    wu       0             0(0/0/0)             05.磁盘镜像(数据同步)
目前系统只有一块磁盘在正常工作:
-3.2# zpool status   
pool: rpool
state: DEGRADED
status: One or more devices are faulted in response to persistent errors.
    Sufficient replicas exist for the pool to continue functioning in a
    degraded state.
action: Replace the faulted device, or use 'zpool clear' to mark the device
    repaired.
scan: resilvered 197G in 2h24m with 0 errors on Fri May 12 19:15:56 2017
config:
    NAME          STATE   READ WRITE CKSUM
    rpool         DEGRADED   0   0   0
      mirror-0    DEGRADED   0   0   0
      c0t0d0s0FAULTED      9   618   0too many errors
      c0t1d0s0ONLINE       0   0   0

errors: No known data errors将新换的磁盘加入存储池,制作磁盘镜像,开始数据拷贝
-3.2# zpool replace rpool c0t0d0s0
Make sure to wait until resilver is done before rebooting.
bash-3.2# zpool status
pool: rpool
state: DEGRADED
status: One or more devices is currently being resilvered.The pool will
    continue to function, possibly in a degraded state.
action: Wait for the resilver to complete.
scan: resilver in progress since Mon Dec 11 11:46:11 2017
   12.4M scanned out of 144G at 906K/s, 46h25m to go
   12.2M resilvered, 0.01% done
config:

    NAME                STATE   READ WRITE CKSUM
    rpool               DEGRADED   0   0   0
      mirror-0          DEGRADED   0   0   0
      replacing-0   DEGRADED   0   0   0
          c0t0d0s0/oldFAULTED      9   618   0too many errors
          c0t0d0s0      ONLINE       0   0   0(resilvering)
      c0t1d0s0      ONLINE       0   0   0

errors: No known data errors
bash-3.2# iostat -xn 3
                extended device statistics            
r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t%w%b device
1.0    4.8   39.9   79.30.00.2    0.0   28.1   0   3 c0t0d0
1.5    6.7   35.0114.80.00.2    0.0   23.5   0   3 c0t1d0
0.0    0.0    0.7    0.00.00.0    0.0    2.8   0   0 c3t60060E8005638900000063890000000Cd0
2.0    1.0    1.0    0.50.00.0    0.0    0.3   0   0 c3t60060E80056389000000638900000008d0
0.0    0.0    0.0    0.00.00.0    0.0    0.2   0   0 c3t60060E80056389000000638900000000d0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t600507640081002FC0000000000000FCd0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 rdms02b:vold(pid523)
                extended device statistics            
r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t%w%b device
0.0358.8    0.0 10546.30.08.4    0.0   23.3   098 c0t0d0
475.3   37.0 10446.3392.80.02.2    0.0    4.2   056 c0t1d0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t60060E8005638900000063890000000Cd0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t60060E80056389000000638900000008d0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t60060E80056389000000638900000000d0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t600507640081002FC0000000000000FCd0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 rdms02b:vold(pid523)
                extended device statistics            
r/s    w/s   kr/s   kw/s wait actv wsvc_t asvc_t%w%b device
0.0405.2    0.0 11338.20.09.1    0.0   22.4   0 100 c0t0d0
647.6    0.0 11317.5    0.00.01.4    0.0    2.1   044 c0t1d0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t60060E8005638900000063890000000Cd0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t60060E80056389000000638900000008d0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t60060E80056389000000638900000000d0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 c3t600507640081002FC0000000000000FCd0
0.0    0.0    0.0    0.00.00.0    0.0    0.0   0   0 rdms02b:vold(pid523

bash-3.2# zpool status
pool: backup
state: ONLINE
scan: none requested
config:

    NAME                                     STATE   READ WRITE CKSUM
    backup                                 ONLINE       0   0   0
      c3t60060E8005638900000063890000000Cd0ONLINE       0   0   0
errors: No known data errors
pool: rpool
state: DEGRADED
status: One or more devices is currently being resilvered.The pool will
    continue to function, possibly in a degraded state.
action: Wait for the resilver to complete.
scan: resilver in progress since Mon Dec 11 11:46:11 2017
107G scanned out of 144G at 17.5M/s, 0h36m to go
107G resilvered, 73.92% done
config:

    NAME                STATE   READ WRITE CKSUM
    rpool               DEGRADED   0   0   0
      mirror-0          DEGRADED   0   0   0
      replacing-0   DEGRADED   0   0   0
          c0t0d0s0/oldFAULTED      9   618   0too many errors
          c0t0d0s0      ONLINE       0   0   0(resilvering)
      c0t1d0s0      ONLINE       0   0   0

errors: No known data errors数据同步完成后如下所示,磁盘更换完毕
-3.2# zpool status
pool: backup
state: ONLINE
scan: none requested
config:

    NAME                                     STATE   READ WRITE CKSUM
    backup                                 ONLINE       0   0   0
      c3t60060E8005638900000063890000000Cd0ONLINE       0   0   0

errors: No known data errors

pool: rpool
state: ONLINE
scan: resilvered 144G in 2h10m with 0 errors on Mon Dec 11 13:56:43 2017
config:

    NAME          STATE   READ WRITE CKSUM
    rpool         ONLINE       0   0   0
      mirror-0    ONLINE       0   0   0
      c0t0d0s0ONLINE       0   0   0
      c0t1d0s0ONLINE       0   0   0

errors: No known data errors6.硬盘测试
重启系统,在xscf界面下,用新换的磁盘启动系统,若启动无问题,则磁盘更换成功:
{0} ok boot disk0
Boot device: /pci@0,600000/pci@0/scsi@1/disk@0File and args:

            </div>
      